Predicting the performance of large steam turbine-generators operating with saturated and low superheat steam conditions: presented at the 29th Annual Meeting of the American Power Conference, April 25-27, 1967, Chicago, Illinois
Gespeichert in:
Beteiligte Personen: | , , |
---|---|
Format: | Buch |
Sprache: | Englisch |
Veröffentlicht: |
Schenectady, N.Y.
Large Steam Turbine-Generator Department, General Electric
[1967]
|
Schlagwörter: | |
Beschreibung: | Der Inhalt dieses 64 Seiten umfassenden Preprints ist nicht inhaltsgleich mit dem gleichnamigen, 9 Seiten umfassenden Beitrag in Proceedings of the American Power Conference, Volume 29, 1967, S. 272-279. Vgl. dort S. 272: "The paper, as preprinted for distribution at the Conference, was 64 pages in length and contained 26 figures which greatly exceeded the publication limits of the APC Proceedings. [...] The paper as printed follows the verbal presentation. Rather than attempting to condense the preprint, the authors have delineated why the paper was written, described the derivation of the major efficiency curves compromising the method, and outlined the application of the method." |
Umfang: | 64 Seiten Illustrationen, Diagramme |
Internformat
MARC
LEADER | 00000nam a2200000 c 4500 | ||
---|---|---|---|
001 | BV049576978 | ||
003 | DE-604 | ||
005 | 00000000000000.0 | ||
007 | t| | ||
008 | 240220s1967 xx a||| |||| 10||| eng d | ||
035 | |a (OCoLC)1424556814 | ||
035 | |a (DE-599)BVBBV049576978 | ||
040 | |a DE-604 |b ger |e rda | ||
041 | 0 | |a eng | |
049 | |a DE-91G | ||
100 | 1 | |a Baily, F. G. |e Verfasser |4 aut | |
245 | 1 | 0 | |a Predicting the performance of large steam turbine-generators operating with saturated and low superheat steam conditions |b presented at the 29th Annual Meeting of the American Power Conference, April 25-27, 1967, Chicago, Illinois |c F.G. Baily, K.C. Cotton and R.C. Spencer (Large Steam Turbine-Generator Department, General Electric Company, Schenectady, New York) |
264 | 1 | |a Schenectady, N.Y. |b Large Steam Turbine-Generator Department, General Electric |c [1967] | |
300 | |a 64 Seiten |b Illustrationen, Diagramme | ||
336 | |b txt |2 rdacontent | ||
337 | |b n |2 rdamedia | ||
338 | |b nc |2 rdacarrier | ||
500 | |a Der Inhalt dieses 64 Seiten umfassenden Preprints ist nicht inhaltsgleich mit dem gleichnamigen, 9 Seiten umfassenden Beitrag in Proceedings of the American Power Conference, Volume 29, 1967, S. 272-279. Vgl. dort S. 272: "The paper, as preprinted for distribution at the Conference, was 64 pages in length and contained 26 figures which greatly exceeded the publication limits of the APC Proceedings. [...] The paper as printed follows the verbal presentation. Rather than attempting to condense the preprint, the authors have delineated why the paper was written, described the derivation of the major efficiency curves compromising the method, and outlined the application of the method." | ||
655 | 7 | |0 (DE-588)1071861417 |a Konferenzschrift |2 gnd-content | |
700 | 1 | |a Cotton, K. C. |e Verfasser |4 aut | |
700 | 1 | |a Spencer, Robert Clark |d 1907- |e Verfasser |0 (DE-588)128968605 |4 aut | |
943 | 1 | |a oai:aleph.bib-bvb.de:BVB01-034921995 |
Datensatz im Suchindex
DE-BY-TUM_call_number | 0701 0024 B 303 |
---|---|
DE-BY-TUM_katkey | 2783467 |
DE-BY-TUM_location | Mag |
DE-BY-TUM_media_number | 040009574963 |
_version_ | 1821934412098437121 |
any_adam_object | |
author | Baily, F. G. Cotton, K. C. Spencer, Robert Clark 1907- |
author_GND | (DE-588)128968605 |
author_facet | Baily, F. G. Cotton, K. C. Spencer, Robert Clark 1907- |
author_role | aut aut aut |
author_sort | Baily, F. G. |
author_variant | f g b fg fgb k c c kc kcc r c s rc rcs |
building | Verbundindex |
bvnumber | BV049576978 |
ctrlnum | (OCoLC)1424556814 (DE-599)BVBBV049576978 |
format | Book |
fullrecord | <?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01939nam a2200289 c 4500</leader><controlfield tag="001">BV049576978</controlfield><controlfield tag="003">DE-604</controlfield><controlfield tag="005">00000000000000.0</controlfield><controlfield tag="007">t|</controlfield><controlfield tag="008">240220s1967 xx a||| |||| 10||| eng d</controlfield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(OCoLC)1424556814</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-599)BVBBV049576978</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-604</subfield><subfield code="b">ger</subfield><subfield code="e">rda</subfield></datafield><datafield tag="041" ind1="0" ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="049" ind1=" " ind2=" "><subfield code="a">DE-91G</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Baily, F. G.</subfield><subfield code="e">Verfasser</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Predicting the performance of large steam turbine-generators operating with saturated and low superheat steam conditions</subfield><subfield code="b">presented at the 29th Annual Meeting of the American Power Conference, April 25-27, 1967, Chicago, Illinois</subfield><subfield code="c">F.G. Baily, K.C. Cotton and R.C. Spencer (Large Steam Turbine-Generator Department, General Electric Company, Schenectady, New York)</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="a">Schenectady, N.Y.</subfield><subfield code="b">Large Steam Turbine-Generator Department, General Electric</subfield><subfield code="c">[1967]</subfield></datafield><datafield tag="300" ind1=" " ind2=" "><subfield code="a">64 Seiten</subfield><subfield code="b">Illustrationen, Diagramme</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="b">n</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="b">nc</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="500" ind1=" " ind2=" "><subfield code="a">Der Inhalt dieses 64 Seiten umfassenden Preprints ist nicht inhaltsgleich mit dem gleichnamigen, 9 Seiten umfassenden Beitrag in Proceedings of the American Power Conference, Volume 29, 1967, S. 272-279. Vgl. dort S. 272: "The paper, as preprinted for distribution at the Conference, was 64 pages in length and contained 26 figures which greatly exceeded the publication limits of the APC Proceedings. [...] The paper as printed follows the verbal presentation. Rather than attempting to condense the preprint, the authors have delineated why the paper was written, described the derivation of the major efficiency curves compromising the method, and outlined the application of the method."</subfield></datafield><datafield tag="655" ind1=" " ind2="7"><subfield code="0">(DE-588)1071861417</subfield><subfield code="a">Konferenzschrift</subfield><subfield code="2">gnd-content</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Cotton, K. C.</subfield><subfield code="e">Verfasser</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Spencer, Robert Clark</subfield><subfield code="d">1907-</subfield><subfield code="e">Verfasser</subfield><subfield code="0">(DE-588)128968605</subfield><subfield code="4">aut</subfield></datafield><datafield tag="943" ind1="1" ind2=" "><subfield code="a">oai:aleph.bib-bvb.de:BVB01-034921995</subfield></datafield></record></collection> |
genre | (DE-588)1071861417 Konferenzschrift gnd-content |
genre_facet | Konferenzschrift |
id | DE-604.BV049576978 |
illustrated | Illustrated |
indexdate | 2024-12-20T20:15:51Z |
institution | BVB |
language | English |
oai_aleph_id | oai:aleph.bib-bvb.de:BVB01-034921995 |
oclc_num | 1424556814 |
open_access_boolean | |
owner | DE-91G DE-BY-TUM |
owner_facet | DE-91G DE-BY-TUM |
physical | 64 Seiten Illustrationen, Diagramme |
publishDate | 1967 |
publishDateSearch | 1967 |
publishDateSort | 1967 |
publisher | Large Steam Turbine-Generator Department, General Electric |
record_format | marc |
spellingShingle | Baily, F. G. Cotton, K. C. Spencer, Robert Clark 1907- Predicting the performance of large steam turbine-generators operating with saturated and low superheat steam conditions presented at the 29th Annual Meeting of the American Power Conference, April 25-27, 1967, Chicago, Illinois |
subject_GND | (DE-588)1071861417 |
title | Predicting the performance of large steam turbine-generators operating with saturated and low superheat steam conditions presented at the 29th Annual Meeting of the American Power Conference, April 25-27, 1967, Chicago, Illinois |
title_auth | Predicting the performance of large steam turbine-generators operating with saturated and low superheat steam conditions presented at the 29th Annual Meeting of the American Power Conference, April 25-27, 1967, Chicago, Illinois |
title_exact_search | Predicting the performance of large steam turbine-generators operating with saturated and low superheat steam conditions presented at the 29th Annual Meeting of the American Power Conference, April 25-27, 1967, Chicago, Illinois |
title_full | Predicting the performance of large steam turbine-generators operating with saturated and low superheat steam conditions presented at the 29th Annual Meeting of the American Power Conference, April 25-27, 1967, Chicago, Illinois F.G. Baily, K.C. Cotton and R.C. Spencer (Large Steam Turbine-Generator Department, General Electric Company, Schenectady, New York) |
title_fullStr | Predicting the performance of large steam turbine-generators operating with saturated and low superheat steam conditions presented at the 29th Annual Meeting of the American Power Conference, April 25-27, 1967, Chicago, Illinois F.G. Baily, K.C. Cotton and R.C. Spencer (Large Steam Turbine-Generator Department, General Electric Company, Schenectady, New York) |
title_full_unstemmed | Predicting the performance of large steam turbine-generators operating with saturated and low superheat steam conditions presented at the 29th Annual Meeting of the American Power Conference, April 25-27, 1967, Chicago, Illinois F.G. Baily, K.C. Cotton and R.C. Spencer (Large Steam Turbine-Generator Department, General Electric Company, Schenectady, New York) |
title_short | Predicting the performance of large steam turbine-generators operating with saturated and low superheat steam conditions |
title_sort | predicting the performance of large steam turbine generators operating with saturated and low superheat steam conditions presented at the 29th annual meeting of the american power conference april 25 27 1967 chicago illinois |
title_sub | presented at the 29th Annual Meeting of the American Power Conference, April 25-27, 1967, Chicago, Illinois |
topic_facet | Konferenzschrift |
work_keys_str_mv | AT bailyfg predictingtheperformanceoflargesteamturbinegeneratorsoperatingwithsaturatedandlowsuperheatsteamconditionspresentedatthe29thannualmeetingoftheamericanpowerconferenceapril25271967chicagoillinois AT cottonkc predictingtheperformanceoflargesteamturbinegeneratorsoperatingwithsaturatedandlowsuperheatsteamconditionspresentedatthe29thannualmeetingoftheamericanpowerconferenceapril25271967chicagoillinois AT spencerrobertclark predictingtheperformanceoflargesteamturbinegeneratorsoperatingwithsaturatedandlowsuperheatsteamconditionspresentedatthe29thannualmeetingoftheamericanpowerconferenceapril25271967chicagoillinois |
Paper/Kapitel scannen lassen
Bibliotheksmagazin
Signatur: |
0701 0024 B 303
Lageplan |
---|---|
Exemplar 1 | Ausleihbar Am Standort |